Tulip System

Tulip cell friendly, the gold standard in cannulas

  • Tulip offers the ability to create the cannula you want. Simply specify the name the hub style the diameter and length when ordering. Call us about custom configurations.
  • Hubs: 60cc-35cc. superluerlok.luer
  • Cannulas: outside diameters in millimeters: 1.6-2.1-2.4-3.7-4.6
  • Standard lengths: in centimeters: 4-5-6-7-8-9-10-12-15-20-25-30-35
  • Tumescent infiltrator:
    Used specifically for the infusion of tumescent solution and for hydraulic dissection. The port configuration port allows even distribution of the fluid.
  • Tonnard harvester:
    A multiport harvester with 1mm elevated sharp microports. The 12 or 20 port configuration allows for harvesting both on the forward and backward strokes.
  • Sorenson harvester:
    A multiport harvester with 1mm depressed sharp microports. The 12 or 20 port configuration allows for harvesting both on the forward and backward strokes.
  • Caraway harvester:
    Spiral three port design is effective for multi-plane tissue harvesting.
  • Triport harvester:
    Excellent for harvesting small aliquots of tissue.
  • Cobra bibevel:
    More aggressive than the standard, pyramid or Mercedes, this cannula has a tapered tip with two ports and works effectively within dense fiburous tissue.
  • Cobra roud tip:
    Less aggressive than the cobra bibevel this cannula has a rounded tip with two ports and works effectively within dense fibrous tissue.
  • Standard:
    This is the most common cannula design for soft tissue removal. The single port is located 180 degrees from the thumb rest on the hub.
  • Pyramid:
    This commonly used design has three ports located 180 degrees from the thumb print. It is slightly more aggressive cannulas than the standard.
  • Mercedes:
    This circumferential three port configuration is effective for multi-plane soft tissue harvesting.
  • Field bilevel infiltrator:
    Used in dermatological surgery to remove tumors and scar tissue.
  • Flap:
    The flap is primarily used as an undermining dissector, and in smaller diameters, for facial tissue removal.
  • Filed flap:
    An elevated leading edge on these cannulas is designed to open and expose soft tissue for more precise suctioning along the mandible and sub-mental areas.
  • Toledo v-dissector:
    This cannula is specifically designed for use in the superficial compartment. The cutting notch is very useful for releasing dense fibrous tissue.

Tulip micro-injectors

  • injectors outside diameters in millimeters: 0.7-0.9-1.2-1.4-1.6-2.1
  • standard lengths in centimeters:4-5-6-7-8-10-12-15
  • Tulip injector:
    Rounded blunt tip design passes through soft tissue easily without the trauma or potential problems of sharp injectors.
  • Little injector:
    Blunt injector designed for precision delivery of very small allquots of tissue especially useful in the periorbital region and the vermillion skin border of the lips.
  • Tulip blunt filler injector:
    Blunt end single port injector designed to administer intradermal fillers safely.
  • Spoon tip injector:
    Blunt injector designed with a more open port for rapid injection of larger volumes- a breast and buttock work house.
  • Blunt & sharp extractor/injector:
    This tip works well for needle extraction of soft tissue and as a soft issue reinjection needle.
  • Pocar:
    The pocar is a percutaneous punch that is used to make a circumferential incision prior to infiltration and tissue extraction. It is designed to maintain a tight seal while minimizing scarring.

Machine, syringe, or both- tulip instrument offer superior results Tulip power handles:

  • 60cc hub tulip cannulas can be attached to our light weight polymer power handle designed for machine liposuction. This perfectly balanced handle combined with our liposculpting and soft tissue enhancement.
  • The friction hub grip allows you to quickly change to different cannulas during your procedures. No need to stop and detach the hose and handle, just switch up your sculpting cannulas with a quick twist off and on.
  • Power adaptor:
    The tulip power adaptor modifies the cannulas and the syringe for use with an aspirating machine.
    • 60cc monoject
    • 35cc moniject
    • 20cc BD
    • 20cc monoject
    • 10cc BD
    • 10/12cc monoject
  • Tulip emulsifier:
    The tulip emulsifier standardizes the texture of harvested tissue for easy and smooth intradermal injection with a 23g needle.
    Anaerobic transfer:
    Anaerobic transfers are used to prepare and transfer extracted tissue for re-injection. The decant stand design also allows for a natural gravity decant.
  • Decant stands:
    • 60cc to 60cc
    • 60cc to luer
    • luer to luer
    • luer to 60cc new!
  • Anaerobic transfers:
    • luer to luer
  • Tulip syringe line:
    We offer a full line of syringe for use with liposuction cannulas, micro injectors and accessories.
    A. 60cc Toomey monoject syringe-box of 20
    B. 60cc luer monoject syringe- box of 20
    C. 35cc catheter monoject syringe- box of 30
    D. 35cc luer monoject syringe-box of 30
    E. 20cc luer monoject syringe-box of 50
    F. 20cc luer BD syringe- box of 40
    G. 12cc luer monoject syringe- box of 80
    H. 10cc luer BD syringe-box of 100
    I. 10cc oral medication monoject syringe (non-sterile)-box of 100
    J. 3cc luer monoject syringe-box of 100
    K. 1cc luer BD polycarbonate syringe- box of 100
  • Johnnie lok:
    The unique, light-weight Johnnie lok slips onto the collar of the syringe barrel. The plunger is drawn back to the desired cc for precision measurement on the syringe. Then, with a small twist, teeth on the lock bite into the plunger flanges and lock the plunger securely to the barrel holding the syringe under vacuum for precision extraction.
  • Snap loks:
    These syringe snap locks fir into the plunger flanges of the syringe. When the plunger is pulled out the lock snaps open on then barrel lip holding the syringe under vacuum.

Introducing the new tulip z stand!

  • No assemble required- easy to clean- virtually inderstrucible
  • Tulip reusable large colume decanting canisters:
    These reusable canisters work with your suction machine to collect measure, decant and transfer in one simple step. Folding stand for convenient autoclaving and storage.

Single-use large volume decanting canisters:

  • Tissue –trans filtron units:
    3 sixes available 500cc, 1000cc, 2000cc closed system with proven filtering and flat viability, no centrifuge needed.
  • Tissue –trans stands:
    34” and 52” to raise the sterile field
  • Tissue- trans mega 1500cc:
    All material collected in a sterile bag, decant and process in physician’s preferred method.
  • Tissue- trans syringe fill 360cc:
    Harvest fat directly into re-injection syringes. Closed system with no mess or transfers.
  • Universal power injector:
    The power injector allows the surgeon to re-inject soft tissue through large or small diameter injectors with very little effort and maximum control. The universal power injector will hold a 10cc or a 20cc BD syringe or a 60cc monoject syringe.
  • Tulip variable speed centrifuge:
    This centrifuge is the perfect compliment to your cell friendly tool kit. Accurate speed up to 3,300rpm/12g’s five you proper separations without cell damage and makes this unit ideal for rejuvenation and regenerative medicine procedures.
  • Autoclave trays:
    Tulip offers variety of autoclave trays suitable for different instrument sizes and instrument sets.
  • Chinupps:
    The number one choice of patients.
    • Comfortable fit does not obstruct ears.
    • Easy one-step application
    • Smooth, soft lycra under-chin compression panel
    • One size fits most patients
    • Highest quality fabric which maintains its elasticity

    • Latex free
    • Use after submental liposculpture and face lifts.
  • Tender foam:
    Hypoallergenic, non-adhesive closed cell post-op foam. Virtually eliminates bruising after liposuction procedures.

Tulip gems premium single use cellfriendly instruments:

  • Tulip’s patent pending cellfriendly technology is now available in premium, pre-sterilized, single use instruments. Tulip gems eliminate risk of cross contamination while providing top of the line performance.
Tulip gems, glide easily through tissue and resist clogging. The proprietary lubricious stealth coating truly is cell friendly. Tulip gems – simply the best.
  • Tumescent infiltrator:
    This cannulas is used specifically for the infusion of tumescent solution and for hydraulic dissection. The configuration of the ports allows even distribution of the fluid.
  • Tonnard harvester:
    A multiport harvester with 1mm elevated sharp microports. The 20 port configuration allows for harvesting both on the forward and backward strokes.
  • Triport harvester:
    Excellent for harvesting small aliquots of tissue.
  • Carraway:
    Spiral three port design is effective for multi-plane tissue harvesting.
  • Tulip injector:
    Rounded blunt tip design passes through soft tissue easily without the trauma or potential problems of sharp injectors.
  • Spoon tip injector:
    Blunt injector designed with a more open port for rapid injection of larger volumes- a breast and buttock workhouse.
  • Johnnie snap:
    The Johnnie snap syringe lock is designed to maintain vacuum at variable pressure levels, from low to high. The Johnnie snap comes in two sizes, 20cc and 60cc, and fits the following syringes:
    • 20cc BD syringes
    • 20cc monoject syringes
    • 60cc BD syringes
    • 60cc monoject syringes
  • Why tulip single use instrument:
    Over time reusable cannulas can corrode and become more porous, creating potential harbors for microbial growth. Now with tulips premium, single use gems, related risks of infection and cross contamination are virtually eliminated tulip quality in a single use device.